FDA approves Sapien XT for aortic valve-in-valve procedures

The FDA approved the Sapien XT transcatheter heart valve on Oct. 15 for aortic valve-in-valve procedures.

The device (Edwards Lifesciences) was approved in June 2014 for patients at high risk for native aortic valve replacement surgery.

Earlier in the day, Edwards released data on the Sapien XT valve at the Transcatheter Cardiovascular Therapeutics scientific symposium in San Francisco. After one year of follow up in the PARTNER II trial, the all-cause mortality rate was 13.4 percent, the stroke rate was 3.7 percent and the hospitalization rate was 11.8 percent.

The study included 197 patients: 97 enrolled in the valve-in-valve registry at 24 sites between June 2012 and April 2013 and 100 enrolled in the extended registry at 34 sites between May 2013 and December 2013. The mean age of patients was 78.5, while 95.4 percent had New York Heart Association Class III or IV heart failure, 70.6 percent had coronary artery disease and 49.7 percent had atrial fibrillation.

The most common procedural complications were major bleeding (14.8 percent of patients), acute kidney injury (8.2 percent), major vascular complications (3.1 percent), pacemakers (1.5 percent), need for a second transcatheter heart valve (1.5 percent) and coronary obstruction (0.5 percent).

The researchers said that valve-in-valve transcatheter aortic valve replacement is an option for patients with failing surgical bioprosthetic valves.

Tim Casey,

Executive Editor

Tim Casey joined TriMed Media Group in 2015 as Executive Editor. For the previous four years, he worked as an editor and writer for HMP Communications, primarily focused on covering managed care issues and reporting from medical and health care conferences. He was also a staff reporter at the Sacramento Bee for more than four years covering professional, college and high school sports. He earned his undergraduate degree in psychology from the University of Notre Dame and his MBA degree from Georgetown University.

Around the web

Eleven medical societies have signed on to a consensus statement aimed at standardizing imaging for suspected cardiovascular infections.

Kate Hanneman, MD, explains why many vendors and hospitals want to lower radiology's impact on the environment. "Taking steps to reduce the carbon footprint in healthcare isn’t just an opportunity," she said. "It’s also a responsibility."

Philips introduced a new CT system at ECR aimed at the rapidly growing cardiac CT market, incorporating numerous AI features to optimize workflow and image quality.

Trimed Popup
Trimed Popup